Euchner CES-AR-C01-EH-SA (Fixcode) Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sécurité Euchner CES-AR-C01-EH-SA (Fixcode). EUCHNER CES-AR-C01-EH-SA (Fixcode) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - CES-AR-C01-EH-SA (Fixcode)

More than safety.Operating InstructionsNon-Contact Safety SwitchCES-AR-C01-EH-SA (Fixcode)

Page 2 - Contents

Operating Instructions Safety Switch CES-AR-C01-EH-SA10Caution! Ì Power devices which are a powerful source of interference must be installed in a sep

Page 3 - Correct use

Operating Instructions Safety Switch CES-AR-C01-EH-SA11Requirements for connection cablesCaution!Risk of damage to equipment or malfunctions as a resu

Page 4

Operating Instructions Safety Switch CES-AR-C01-EH-SA12Determining cable lengths using the example tableExample: 6 switches are to be used in series.

Page 5 - General safety instructions

Operating Instructions Safety Switch CES-AR-C01-EH-SA13Connector assignment of safety switch CES-ARCoding lugView on the connection side of the safety

Page 6 - Function

Operating Instructions Safety Switch CES-AR-C01-EH-SA14Connection of a single CES-AR-CIf a single CES-AR-C is used, connect the switch as shown in Fig

Page 7

Operating Instructions Safety Switch CES-AR-C01-EH-SA15Warning!In the event of a fault: Loss of the safety function due to incorrect connection. Ì To

Page 8 - Mounting

Operating Instructions Safety Switch CES-AR-C01-EH-SA16Connection of several CES-AR-C in a switch chainImportant! Ì An AR switch chain may contain a m

Page 9 - Electrical connection

Operating Instructions Safety Switch CES-AR-C01-EH-SA17Figure 5: Connection example for series connection with reset and changeover switch.Y-distribu

Page 10 - Safety in case of faults

Operating Instructions Safety Switch CES-AR-C01-EH-SA18Notes on operation with safe control systemsPlease observe the following requirements for conne

Page 11 - Maximum cable lengths

Operating Instructions Safety Switch CES-AR-C01-EH-SA19Safety OutputRead HeadSafety InputsRead HeadSafety OutputSafetyInputsSafetyInputsSafety OutputY

Page 12 - = min. 75 mA

Operating Instructions Safety Switch CES-AR-C01-EH-SA2ContentsCorrect use 3Possible combinations for CES components 4Exclusion of liability and warr

Page 13 - Coding lug

Operating Instructions Safety Switch CES-AR-C01-EH-SA20SetupLED indicatorsLED Color State SignificanceSTATEgreenillumi-natedNormal operationflashing- Te

Page 14 - M12 plug-connector

Operating Instructions Safety Switch CES-AR-C01-EH-SA21System status tableOperating modeActuator/door posi-tionSafety outputs OA and OBLED indicator,

Page 15 - CES-AR #1

Operating Instructions Safety Switch CES-AR-C01-EH-SA22Technical dataNote:If a product data sheet is included with the product, the information on the

Page 16

Operating Instructions Safety Switch CES-AR-C01-EH-SA23Typical system timesThe specified times are maximum values for AR switch chains with 20 devices.

Page 17 - CES CESCES

Operating Instructions Safety Switch CES-AR-C01-EH-SA24Dimension drawings and connector assignments4040,556,5133420,5M12x174730Ø5,5Safety switch CES-A

Page 18

Operating Instructions Safety Switch CES-AR-C01-EH-SA25Assigned actuatorTechnical data for actuator CES-A-BPAParameter Value Unitmin. typ. max.Housing

Page 19 - CET) on ET200

Operating Instructions Safety Switch CES-AR-C01-EH-SA26Switching distancesOperating distance for center offset m = 0(only in conjunction with actuator

Page 20 - Functional check

Operating Instructions Safety Switch CES-AR-C01-EH-SA27Ordering information and accessoriesDesignation Version Order No.CES-AR-C01-EH-SA including act

Page 21 - System status table

Operating Instructions Safety Switch CES-AR-C01-EH-SA28ServiceIf service support is required, please contact:EUCHNER GmbH + Co. KGKohlhammerstraße 16D

Page 22 - Technical data

Operating Instructions Safety Switch CES-AR-C01-EH-SA29Declaration of conformity

Page 23 - Typical system times

Operating Instructions Safety Switch CES-AR-C01-EH-SA3Correct useThe Coded Electronic Safety switches series CES are safety devices for monitor-ing mo

Page 24 - Plug Socket

Operating Instructions Safety Switch CES-AR-C01-EH-SA30

Page 25 - Assigned actuator

Operating Instructions Safety Switch CES-AR-C01-EH-SA31

Page 26

More than safety.Euchner GmbH + Co. KGKohlhammerstraße 16D-70771 [email protected]:103488-09-10/13Title: Ope

Page 27 - Inspection and service

Operating Instructions Safety Switch CES-AR-C01-EH-SA4Important! Ì In the case of series connection of more than 11 devices, the PFHd can be calculate

Page 28

Operating Instructions Safety Switch CES-AR-C01-EH-SA5Exclusion of liability and warrantyIn case of failure to comply with the conditions for correct

Page 29 - Declaration of conformity

Operating Instructions Safety Switch CES-AR-C01-EH-SA6FunctionThe device complies with the following safety requirements: Ì Category 4, PLe according

Page 30

Operating Instructions Safety Switch CES-AR-C01-EH-SA7Changing the approach directionCaution!Risk of damage to equipment as a result of trapped cables

Page 31

Operating Instructions Safety Switch CES-AR-C01-EH-SA8MountingImportant! Ì From the assured switch-off distance Sar, the safety outputs are safely shu

Page 32 - More than safety

Operating Instructions Safety Switch CES-AR-C01-EH-SA9Electrical connectionThe following connection options are available: Ì Separate operation Ì Seri

Commentaires sur ces manuels

Pas de commentaire