Evaluation unit CES-A-UEA-04B
Ì Housing for DIN rail mounting, IP 20
Ì Relay output
Ì 4 read heads can be connected
Dimension drawing
Switching characteristics
Ì
2 safety outputs
(relay outputs)
Ì 4 door monitoring outputs
(semiconductor outputs,
not safety outputs)
Approvals
45
99
114
Suitable for 35-mm DIN rail according to EN 60715
Safety guard
closed
(all actuators detected)
Open
(e.g. actuator 1 not in the oper-
ating distance)
Read head 1 Actuator 1 Read head 1
13
14
23
24
24 V O 1
13
14
23
24
24
VO1
24 V O 2 24 V O 2
24 V O 3 24 V O 3
24 V O 4 24 V O 4