Euchner CES-A-W5H-01 (Multicode) Manuel d'utilisateur Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
System Manual Safety System CES-A-W5H-01
24
Typical operating distance
Only in combination with actuator CES-A-BBA or CES-A-BCA
Operating distance for center offset m = 0
1)
Parameter
Value
Unit
min. typ. max.
Assured switch-on distance S
ao
18 - -
mm
Switch-on distance - 20 -
Switching hysteresis 2 3 -
Assured switch-off distance S
ar
- - 40
1) The values apply for surface installation of the actuator.
X
25
15
20
10
5
20
25
30
5
10
15
-30
30
-30
25
20
15
10
5
Y
Z
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.