Operating Instructions Safety Switch CES-AP-C.2-CH
21
Technical data for actuator CES-A-BDN
Parameter Value Unit
min. typ. max.
Housing material Macromelt PA-based plastic
Dimensions 26 x ∅ 6 mm
Weight 0.005 kg
Ambient temperature - 40 - + 70 °C
Degree of protection
acc. to EN IEC 60529
IP67 / IP69K
1)
Installation position Active face opposite read head
Power supply Inductive via read head
1) With flush installation
Dimension drawing
Caution!
Do not mount at temperatures below 0 °C.
The actuator can be damaged during mounting.
Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BDN-...)
Parameter Value Unit
min. typ. max.
Switch-on distance - 19 -
mm
Assured switch-on distance s
ao
1)
14 - -
Switching hysteresis
1)
- 2 -
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
Installation options
26
0
+
0,5
Ø
30
* min.
30
*
30
*
6,1
0
+
0,1
z
y
x
6
* metal-free zone
operating distance