Operating Instructions Safety Switch CES-AR-C01-CH-SA
30
Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BRN)
Parameter Value Unit
min. typ. max.
Switch-on distance - 27 -
mm
Assured switch-on distance s
ao
1)
20 - -
Switching hysteresis
1)
- 3 -
Assured switch-off distance s
ar
- - 75
1) The values apply for surface installation of the actuator on steel.
Typical operating distance
(only in conjunction with actuator CES-A-BRN on surface mounting on steel)
Figure 9: Typical operating distance
5
20
25
30
35
Z
X
5
15
20
50
45
40
35
30
25
50
Y
-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-55
-60
-65
10
5
15
25
30
40
45
50
55
60
65
15
10
10
20
35
For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.