Euchner AS-i 3.0 Command Interface Manuel d'utilisateur Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 98
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
30
4.3.3.13 Command 15: "Safety Status"
With this command the status of safety monitors (external and integrated) in the
version 2 can be read.
Request buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 reserved 00
16
Response buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 reserved 00
16
2
OSSD 1 state
1
1. see table "Coding of status byte", page 30
3
OSSD 2 state
2
2. see table "Coding of status byte", page 30
... ...
n
OSSD n-1 state
3
3. see table "Coding of status byte", page 30
Coding of status byte
Bit [0 ... 2] state and/or colour
0 green permanent light
1 green flashing
2 yellow permanent light
3 yellow flashing
4 red permanent light
5 red flashing
6 grey and/or off
7 reserved
Bit [6] state and/or colour
0 no device flashes yellow in this OSSD
1 at least one device flashes yellow in this OSSD
Bit [7] state and/or colour
0 no device flashes red in this OSSD
1 at least one device flashes red in this OSSD
Vue de la page 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 97 98

Commentaires sur ces manuels

Pas de commentaire