AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
53
4.6 Other commands
4.6.1 Overview of the commands
4.6.2 IDLE
When the value of "command" is zero, no request will be fulfilled.
Values for command
see page Command Value Meaning
Req
Len
Res
Len
page 53
IDLE
00
16
No request 2 2
page 54
READ_IDI
41
16
Read IDI 2 36
page 54
WRITE_ODI
42
16
Write ODI 34 2
page 55
READ_ODI
56
16
Read ODI 2 34
page 55
SET_OFFLINE
0A
16
Set_Off-Line_Mode 3 2
page 56
SET_DATA_EX
48
16
Set_Data_Exchange_Active 3 2
!
page 56
REWRITE_DPRAM
1
1. The command REWRITE_DPRAM is valid only for the use with AS-i 3.0 Module OEM Master
78
16
Rewrite DPRAM 3 3
page 56
BUTTONS
75
16
Disable Pushbuttons 3 2
page 57
FP_PARAM
7D
16
„Functional Profile“ Param. 3 2
page 58
FP_DATA
7E
16
„Functional Profile“ Data 3 2
!
page 58
EXT_DIAG
2
2. The command EXT_DIAG is valid only for the use with AS-i 3.0 PROFIBUS Gateways
71
16
ExtDiag generation 6 2
!
page 59
RD_EXT_DIAG
3
3. The command RD_EXT_DIAG is valid only for the use with AS-i 3.0 PROFIBUS Gateways
7B
16
Read ExtDiag Settings 2 7
page 60
INVERTER
7C
16
Configure Inverter Slaves 12 4
page 60
MB_OP_CTRL_WR_FLAGS
85
16
Write Flags 52
page 61
MB_OP_CTRL_RD_FLAGS
86
16
Read Flags 4 3
page 61
RD_MFK_PARAM
59
16
Read SEW MFK21 Parameter 6 3
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
100
16
2T circuit
Response
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
100
16
2T result